Advertisement

5-2. Response Time Change Function

For FX-301(P)(-HS), response time can be switched
among five levels:
H-SP (ultra high-speed) / FAST (high-speed) / S-D
(reduced intensity) / STD (standard) / LONG (long-range).
For FX-305(P), response time can be switched
among six levels:
H-SP (ultra high-speed) / FAST (high-speed) / STD (standard) /
STDF (standard 2) / LONG (long-range) / U-LG (ultra long-range).
In case of FX-301(P)(-HS)
FAST (high-speed)
S-D (reduced intensity) STD (standard) LONG (long-range)
H-SP (ultra high-speed)
Turn the Jog switch to select
the desired mode.
In case of FX-305(P)
H-SP (ultra high-speed)
FAST (high-speed)
STD (standard) STDF (standard 2) LONG (long- range) U-LG (ultra long-range)
Turn the Jog switch to select the
desired mode.
The digital display will quickly
blink 3 times to confirm the setting.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Mode
Note: If the interference prevention function is set to
become doubled.
Press the MODE
1 Press the [MODE key] 5 times to select 'PRO mode'.
key 5 times.
Turn the Jog switch
once toward the
2 Turn the [Jog switch] once toward the '
'
' direction.
Press the
3 Press the [Jog switch] to enter the 'response time
Jog switch.
Press the
4 If the [Jog switch] is pressed, the current mode will be
Jog switch.
5 If the [Jog switch] is turned, the digital display will blink.
Press the
6 If the [Jog switch] is pressed, the digital display will
Jog switch.
Press the MODE key
3 times or keep it
7 Press the [MODE key] 3 times or keep it pressed for 2 sec.
pressed for 2 sec. or
more.
27
Model No.
FX-301(P)-HS
35 !s
(ultra high-speed)
150 !s
(high-speed)
250 !s
(reduced intensity)
250 !s
(standard)
(standard 2)
2 ms
(long-range)
(ultra long-range)
to select 'PRO1 mode'.
change' state.
displayed.
* FX-301(P)(-HS): The factory setting is 'STD (standard)'.
FX-305(P): The factory setting is 'STDF (standard 2)'.
Select the desired response time.
quickly blink 3 times, confirming the setting.
or more, the amplifier will return to 'RUN mode' (normal
sensing operation).
Response time
FX-301(P)
FX-305(P)(Note)
65 !s
65 !s
150 !s
150 !s
250 !s
250 !s
250 !s
700 !s
2 ms
2.5 ms
4.5 ms