Sunx FX-301 Operation Manual page 8

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

TEACH : Teaching Mode
Refer to p.13 ~ for setting procedure
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
When using FX-305(P) window comparator mode
The 'threshold value' can be set with any of the 3 teaching methods, '1-level
teaching', '2-level teaching' and '3-level teaching'.
values', both ON and OFF can occur between the two threshold value levels.
Output
(L-ON)
1_SL
1-level Teaching
This sets the shift value to any desired value, and sets the threshold values (1_SL,
2_SL) by means of 1-level teaching.
Shift value
1_SL
2_SL
0
P-1
Output
OFF
ON
OFF
(L-ON)
2-level Teaching
This carries out 2-level teaching (P-1, P-2) and sets the threshold values (1_SL,
2_SL).
P-1
P-2
1_SL
2_SL
ON
Output
OFF
ON
OFF
(L-ON)
3-level Teaching
This carries out 3-level teaching (P-1, P-2, P-3) and sets the threshold value
(1_SL) between A and B and the threshold value (2_SL) between B and C as
shown in the diagram below.
After teaching, P-1, P-2 and P-3 are automatically assigned in ascending order to
'A', 'B', and 'C'.
P-1
P-2
P-3
1_SL
2_SL
Output
OFF
ON
OFF
(L-ON)
When using FX-305(P) differential mode
Sensing of only sudden changes in incident light intensity is carried out, so that
this is ideal for sensing edges of object such as glass.
Set to 'full-auto teaching' if teaching is to be carried out. (Refer to p.12 for details.)
Furthermore, if the response time has been set in STDF, LONG or U-LG mode,
mount to make the threshold values to more than the following values.
STDF mode : 40 digits
LONG mode: 60 digits
U-LG mode : 100 digits
7
ON
OFF
Hysteresis
2_SL
Incident light
intensity
4,000 / 9,999
P.13~
Incident light
intensity
4,000 / 9,999
2_SL
P-1
1_SL
0
ON
Output
(L-ON)
OFF
P.15~
Incident light
intensity
4,000 / 9,999
P-2
2_SL
P-1
1_SL
0
ON
Output
(L-ON)
OFF
P.17~
Incident light
intensity
4,000 / 9,999
C
2_SL
B
1_SL
A
0
ON
Output
(L-ON)
OFF
By setting two 'threshold
Shift value
Shift value
Time
* In this figure, the incident
light intensity of P-1 is
less than that of P-2.
Time
Time