Code Setting Function - Sunx FX-301 Operation Manual

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

9-2. Code Setting Function

The input of a 4-digit code allows the configuration to be set directly, without the need to set each individual function.
Output 1 only can be set for FX-305(P).
Press the MODE key
5 times.
Turn the Jog switch 5 times
toward the '
Press the Jog switch.
Press the Jog switch.
Press the Jog switch.
Turn the Jog switch
to select the desired code.
Turn the Jog
switch to select the
desired code.
repeat this motion
(
3 times.
Press the Jog
switch to confirm
the selection.
The digital display will
quickly blink 3 times to
confirm the setting.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
' direction.
)
ex.) FX-301(P): Setting of Code 3013
Response time
: LONG
Hysteresis
: standard
L-ON / D-ON
: L-ON
Display
: Incident
light
intensity
Adjust lock
: ON
Timer operation : OFF-delay
Timer period
: 5 ms
* Refer to p.49 'Code Setting Table'.
1 Press the [MODE key] 5 times to select 'PRO mode'.
2 Turn the [Jog switch] 5 times toward the '
select 'PRO5 mode'.
3 Press the [Jog switch] to enter the 'code setting' state.
4 If the [Jog switch] is pressed, the current setting will be
displayed.
* The factory setting is; FX-301(P): '
5 Press the [Jog switch] to input the 4-digit of the 'code'.
Please refer to the 'Code Setting Table' on p.49, for
information on inputting codes.
6Repeat the following motions: Turn the [Jog switch] to select
the digits, then press the [Jog switch] to confirm each
selection.
Once 4-digit have been input, the digital display will quickly
blink 3 times, confirming the 'code' setting.
7 Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will to return to 'RUN mode' (normal
sensing operation).
51
' direction , to
'
FX-301(P)-HS: '
'
FX-305: '
'

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-301p-hsFx-305Fx-301pFx-305p

Table of Contents