4

Settings for NAVI Mode

4-1. NAVI Mode Functions and Settings

In [NAVI mode], frequently changed settings can be easily configured.
Settings for four functions can be configured.
RUN : Normal Sensing Operation
TEACH : Teaching Mode
Refer to p.10 ~ for setting procedure
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
This indicates normal sensing operation. Incident light intensity is displayed in real
time. The factory setting is that the 'threshold value' cannot be changed directly.
When the 'Adjust Lock Function' in 'PRO5 Mode' is disabled, manual fine adjustment
of the 'threshold value' can be performed during normal sensing operation.
The threshold value can be confirmed by turning the jog switch (Refer to p.59). In
addition, key lock function can also be set (Refer to p.59).
Sensing operation
This mode sets the 'threshold value' by utilizing teaching.
When using FX-301(P)(-HS) or FX-305(P) normal mode
The 'threshold value' can be set with any of the 3 teaching methods, '2-level
teaching', 'limit teaching' and 'full-auto teaching'.
2-level Teaching
P.10
2-level teaching is a method of setting the threshold value by teaching the
amplifier unit two different status conditions - sensing object present and sensing
object absent.
The 'threshold value' is usually set using this method.
Thru-beam type
Sensing object present
Sensing object absent
Limit Teaching
P.11
Teaches only the status condition in which no sensing object is within sensing
range (status in which incident light intensity is stable). This method is used to set
a 'threshold value' for conducting sensing in the presence of a background, or
when extremely small objects are to be detected.
Thru-beam type
Minute
object
Full-auto Teaching
P.12
This method is used to set the threshold value while the sensing objects are still
moving on the production line, without stopping the production line.
Thru-beam type
6
* Sensing operation when 'threshold value'
can be fine adjusted
Refer to the section entitled '9-3. Adjust Lock
Function' from 'PRO5 Mode' on p.52.
Reflective type
Sensing object present
Sensing object absent
Reflective type
Background
Reflective type