Sunx FX-301 Operation Manual page 14

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

4-3. Teaching Mode [when using FX-305(P) window comparator mode]
The 'threshold value' can be set using '1-level teaching', '2-level teaching' or '3-level teaching'. When FX-305(P) is in window
comparator mode, teaching is performed using the teaching methods described in the section entitled '10-2. Output 1 Sensing Mode
Settings' from 'PRO6 Mode' on p.56. To change the teaching method, follow the procedures also described under the same heading.
* Window comparator mode can be set for output 1 only.
* The factory setting is '1-level teaching (
1-level Teaching
Setting in PRO6 mode beforehand
Setting in NAVI mode
The status condition when a sensing object is
present that can be used as a baseline.
To be continued on the next page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
)'.
This is the method of setting the threshold
values (1_SL, 2_SL) by one level (P-1) teaching.
The shift value can be set as desired.
* The shift value units can be selected from two units: 'digit' or '%'.
* The shift value of the factory setting is set to '100' of 'digit' units.
To set the shift value, refer to the section entitled '10-2. Output
1 Sensing Mode Settings' from 'PRO6 Mode' on p.56.
For further details, refer to '10-2. Output 1 Sensing Mode Settings' on p.56.
Press the
MODE key 5 times.
Turn the Jog switch
6 times toward the
'
' direction.
Turn the Jog switch
to select output 1.
Turn the Jog switch
to select window
comparator mode.
Turn the Jog switch
to select 1-level
teaching.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
Press the
MODE key once.
Output 1
Press the
Jog switch.
Incident light
intensity of P-1.
Press the
Jog switch.
Shift value
1_SL
2_SL
P-1
Output
OFF
ON
OFF
(L-ON)
1Press the [MODE key] 5 times to select 'PRO mode'.
2Turn the [Jog switch] 6 times towards the '
select 'PRO mode'.
3Turn the [Jog switch] to select 'output 1', and then press the
[Jog switch] to confirm the setting.
4Turn the [Jog switch] to select 'window comparator mode',
and then press the [Jog switch] to confirm the setting.
5Turn the [Jog switch] to select '1-level teaching', and then
press the [Jog switch] to confirm the setting.
1Press the [MODE key] once to select 'TEACH mode'.
2Press the [Jog switch] to select 'output 1'.
3The current teaching method will be displayed for 0.5 sec.,
and then the unit will enter the 'P-1' setting state.
4If the [Jog switch] is pressed while in the status condition
when a sensing object is present that can be used as a
baseline, then the display will blink and indicate the incident
light intensity reading.
13
Incident light
intensity
9,999
2_SL
P-1
1_SL
0
Output
ON
(L-ON)
OFF
' direction to
Shift value
Shift value
Time