Diagram Of Functions And Settings - Sunx FX-301 Operation Manual

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

2

Diagram of Functions and Settings

2-1. Diagram of Functions and Settings
The amplifier features and settings are generally classified into two main modes; the 'NAVI mode' for items and
settings that are frequently reconfigured, and the 'PRO mode' that contains more detailed settings.
RUN
Run
This indicates normal sensing
operation.
NAVI
mode
PRO
Pro
Allows various detailed settings to be configured, such as
optical communications, save / load and other settings.
Switches
PRO1
times. (Refer to p.27)
P. 24~
Changes the light emitting a-
mount selection setting. (Refer
to p.34)
PRO2
Allows selection of different
content to be indicated in the
P. 35~
digital display. (Refer to p.37)
Loads configuration setting from
PRO3
PRO
the data bank. (Refer to p.41)
P. 40~
mode
Using optical communications, configuration
PRO4
settings from the main unit are copied to
P.43~
connected sub units all at once. (Refer to p.44)
* The FX-301(P)-HS is not
equipped with a PRO4
setting function.
Allows basic configuration information
PRO5
to be set in a single step, by inputting
P.49~
a 4-digit code. (Refer to p.51)
Available only
The items that can be set are different for output 1 and output 2.
in FX-305(P)
PRO6
Sets a threshold value for ON /
OFF operation. (Refer to p.56)
P.55~
Error Output
Output when overcurrent occurs or when
a communication error occurs from
connected incompletely. (Refer to p.58)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
TEACH
The 'threshold value' can be set by utilizing
either '2-level teaching', 'limit teaching' or
'full-auto teaching'. (Refer to p.10~)
* When the FX-305(P) is in window comparator mode,
the 'threshold value' can be set by either '1-level
teaching', '2-level teaching' or '3-level teaching'.
TIMER
Configures operation of the timer.
(Refer to p.23)
Response Time Change
among
response
Light Emitting Amount Selection
Digital Display Setting
Data Bank Load
Copy
Code
Normal Mode
Output 1
Output 2
Alarm Output
Be used as alarm output when the threshold
value for output 2 is linked to output 1 and
the light amount drops. (Refer to p.58)
Teaching
Timer
Timer Setting
Configures timer operation.
(Refer to p.28~)
Shift
Shifts the 'threshold value' by a
certain percentage increment in
'limit teaching'. (Refer to p.33)
Digital Display Inversion
Sets the viewing orientation of
the digital display.
(Refer to p.38)
Data Bank Save
Saves configuration setting into
the data bank. (Refer to p.42)
Remote Data Bank Load
Using optical communication, configuration
settings can be loaded from respective
data banks all at once. (Refer to p.45)
Backup
Allows not to save the threshold
value, by teaching via external
input in EEPROM. (Refer to p.48)
Interference Prevention
Switching
Switches the number of units for which
interference prevention switching is enabled.
* FX-305(P) only. (Refer to p.54)
Window Comparator Mode
Judges if set two threshold values are within the
required range or not. This can be selected in
1-level / 2-level / 3-level teaching. (Refer to p.56)
Trailing Differential Mode
Sensing mode that cancels out slight changes in
light intensity so that only sudden decreases in
incident light intensity are sensed. (Refer to p.56)
2
ADJ
Adjust
Allows fine adjustment of the
'threshold value'. (Refer to p.19~)
L/D
L-ON / D-ON
Sets output operation either Light-
ON, or Dark-ON. (Refer to p.22)
Hysteresis
Sets hysteresis level.
(Refer to p.31)
Stability
Permits selection of stability indicator response
levels for changes in the range for lighting up.
(Refer to p.32) [FX-301(P)(-HS) only]
ECO Mode
Sets the digital display to turn
ON / OFF.
(Refer to p.39)
Remote Data Bank Save
Using optical communication, current configu-
ration settings can be saved into respective
data banks all at once. (Refer to p.46)
Communication Change
To Permit / Not to Permit
When using optical communication for carrying out copy /
load / save operations all at once, this function allows optical
communication to pass through the unit. (Refer to p.47)
Adjust Lock
Allows fine adjustment of the 'threshold
value' to be directly performed during
RUN mode. (Refer to p.52)
Reset
All settings, except for data
bank information, revert to
factory settings. (Refer to p.53)
Rising Differential Mode
Sensing mode that cancels out slight changes in
light intensity so that only sudden increases in
incident light intensity are sensed. (Refer to p.56)