Parameter settings
DisplaySettings
Behavior during control startup
Acknowledge the "Power interrupted" message
TRUE: Run-up is continued only after the message has been acknowledged
FALSE: The "power interrupted" message does not appear
Depiction of the cycles
TNC_STD: Display the cycles with comments
TNC_PARAM: Display the cycles without comments
DisplaySettings
Settings for program-run graphics
Type of graphic display
High (compute-intensive): The orientation of linear and rotary axes is considered for the
graphic display (3-D)
Low: Only the orientation of linear axes is considered for the program-run graphics (2.5-
D).
Disabled: The program-run graphics are deactivated
ProbeSettings
Configuration of probing behavior
Manual operation: Inclusion of basic rotation
TRUE: Including active basic rotation during probing
FALSE: Always move on paraxial path during probing
Automatic mode: Multiple measurements in probing functions
1 to 3 Probe points per probing process
Automatic mode: Confidence range for multiple measurement
0.002 to 0.999 [mm]: Range within which the measured value must be during multiple
measurements
Configuration of a round stylus
Coordinates of the stylus center
[0]: X coordinate of the stylus center with respect to the machine datum
[1]: Y coordinate of the stylus center with respect to the machine datum
[2]: Z coordinate of the stylus center with respect to the machine datum
Safety clearance above the stylus for pre-positioning
0.001 to 99 999.9999 [mm]: Safety clearance in tool axis direction
Safety zone around the stylus for prepositioning
0.001 to 99 999.9999 [mm]: Safety clearance in the plane perpendicular to the tool axis