Circle Center As Datum - HEIDENHAIN TNC 620 User Manual

Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

14
Manual operation and setup
14.9 Datum Setting with 3-D Touch Probe (Touch Probe Function
Software Option)

Circle center as datum

With this function, you can set the datum at the center of bore
holes, circular pockets, cylinders, studs, circular islands, etc.
Inside circle:
The TNC probes the inside wall of a circle in all four coordinate axis
directions.
For incomplete circles (circular arcs) you can choose the
appropriate probing direction.
Position the touch probe approximately in the center of the
circle
Select the touch probe function: Press the
PROBING CC soft key
Select the probing direction or press the soft key
for the automatic probing routine
Probing: Press the machine START button. The
touch probe probes the inside wall of the circle
in the selected direction. If you are not using the
automatic probing routine, you need to repeat this
procedure. After the third probing operation, you
can have the TNC calculate the center (four touch
points are recommended)
Terminate the probing procedure and switch to the
evaluation menu: Press the EVALUATE soft key
Datum: In the menu window, enter both
coordinates of the circle center, confirm with the
SET DATUM soft key, or write the values to a table
(See "Writing measured values from the touch
probe cycles in a datum table", page 469, or See
"Writing measured values from the touch probe
cycles in the preset table", page 470)
Terminate the probing function: Press the END soft
key
The TNC needs only three touch points to calculate
outside or inside circles, e.g. for circle segments.
More precise results are obtained if you measure
circles using four touch points, however. You should
always preposition the touch probe in the center, or
as close to the center as possible.
482
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 3/2014