7 PROFINET Messaging
Bit
Name
0
RDY_ON
1
RDY_RUN
2
RDY_REF
3
TRIPPED
4
OFF_2_STA
5
OFF_3_STA
6
SWC_ON_INHIB
7
ALARM
8
AT_SETPOINT
9
REMOTE
10
ABOVE_LIMIT
11 to 15
–
32
Table 13 Status Word for the PROFIdrive Communication Profile
Value
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
–
–
READY TO SWITCH ON.
NOT READY TO SWITCH ON.
READY TO OPERATE.
OFF1 ACTIVE.
ENABLE OPERATION.
DISABLE OPERATION.
FAULT.
No fault.
OFF2 inactive.
OFF2 ACTIVE.
OFF3 inactive.
OFF3 ACTIVE.
SWITCH-ON INHIBIT ACTIVE.
SWITCH-ON INHIBIT NOT ACTIVE.
Warning/Alarm.
No Warning/Alarm.
OPERATING. Actual value equals reference value (i.e., is within tolerance limits).
Actual value differs from reference value (i.e., is outside tolerance limits).
Drive control location: REMOTE.
Drive control location: LOCAL.
Not supported.
Reserved
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
STATE/Description