6 Related Drive Parameters
No.
(Addr.
Name
Hex)
F7-04
IP Address 4
(3E8)
F7-05
(3E9)
Subnet Mask 1
<7>
F7-06
(3EA)
Subnet Mask 2
<7>
F7-07
(3EB)
Subnet Mask 3
<7>
F7-08
(3EC)
Subnet Mask 4
<7>
F7-09
(3ED)
Gateway Address 1
<7>
F7-10
(3EE)
Gateway Address 2
<7>
F7-11
(3EF)
Gateway Address 3
<7>
F7-12
(3E0)
Gateway Address 4
<7>
F7-13
(3F1)
Address Mode at Startup
<7>
F7-14
Duplex Mode Selection
(3F2)
F7-15
(3F3)
Communication Speed Selection
<8>
F7-23
Dynamic Output Assembly
(3FB)
Parameter 1
<10>
F7-24
Dynamic Output Assembly
(3FC)
Parameter 2
<10>
F7-25
Dynamic Output Assembly
(3FD)
Parameter 3
<10>
F7-26
Dynamic Output Assembly
(3FE)
Parameter 4
<10>
28
Sets the static/fixed IP address.
Parameter F7-04 sets the fourth most significant octet.
Sets the static/fixed Subnet Mask.
Parameter F7-05 sets the most significant octet.
Sets the static/fixed Subnet Mask.
Parameter F7-06 sets the second most significant octet.
Sets the static/fixed Subnet Mask.
Parameter F7-07 sets the third most significant octet.
Sets the static/fixed Subnet Mask.
Parameter F7-08 sets the fourth most significant octet.
Sets the static/fixed Gateway address.
Parameter F7-09 sets the most significant octet.
Sets the static/fixed Gateway address.
Parameter F7-10 sets the second most significant octet.
Sets the static/fixed Gateway address.
Parameter F7-11 sets the third most significant octet.
Sets the static/fixed Gateway address.
Parameter F7-12 sets the fourth most significant octet.
Selects how the option address is set.
0: Static
<7>
2: DCP
Selects duplex mode setting.
0: Auto/Auto
1: Half/Half
2: Full/Full
3: Half/Auto
4: Half/Full
5: Auto/Half
6: Auto/Full
7: Full/Half
8: Full/Auto
Sets the communication speed.
0: 10 Mbps (Available only with drive software version PRG: 1012 to
1015)
1: 10 Mbps
100: 100 Mbps
Sets configurable output 1.
Sets configurable output 2.
Sets configurable output 3.
Sets configurable output 4.
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Description
Values
Default: 20
Min: 0
Max: 255
Default: 255
Min: 0
Max: 255
Default: 255
Min: 0
Max: 255
Default: 255
Min: 0
Max: 255
Default: 0
Min: 0
Max: 255
Default: 192
Min: 0
Max: 255
Default: 168
Min: 0
Max: 255
Default: 1
Min: 0
Max: 255
Default: 1
Min: 0
Max: 255
Default: 2
Range: 0, 2
Default:
<7>
Range: 0 to 8
Default:
<9>
Range:
<9>
Default: 0H
Min.: 0H
Max.: FFFFH
Default: 0H
Min.: 0H
Max.: FFFFH
Default: 0H
Min.: 0H
Max.: FFFFH
Default: 0H
Min.: 0H
Max.: FFFFH