5 Installation Procedure
Communication Cable Specifications
Use only PROFINET dedicated communication cable; the Yaskawa warranty does not cover other cable types.
The use of CAT5e or equivalent Shielded Twisted Pair (STP) cable is recommended.
Option Connection Diagram
<1> Connect the provided ground wire during installation.
Communication Cable Topology
The option modular connector CN1 port 1 and port 2 act as a switch to allow for flexibility in cabling topology. For
example, a traditional star network topology may be employed by using a single port on the option board. Alternatively,
a daisy-chained approach may be employed by using both option modular connector ports. This second approach reduces
the requirements of PROFINET switch ports.
Figure 32
V1000
GSD Files
To facilitate network implementation, obtain a GSD file from one of the following websites depending on your region:
US: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: http://e-mechatronics.com
Other areas: Check the back cover of these manuals.
26
V1000
Power
PROFINET Cable
PROFINET Master
PROFINET Cable
Figure 32 Wiring Diagram
PLC
SWITCH
STOP
STOP
STOP
V1000
V1000
Figure 33 Topology Options
R/L1
U/T1
S/L2
V/T2
T/L3
W/T3
V1000
SI-EP3/V
PROFINET
Option
FE
PLC
V1000
SWITCH
STOP
V1000
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
M
Motor
<1>
STOP
STOP
V1000
V1000