19.
If the angle reading is higher than 25%(14.1°). Take the following steps to
correct: (Refer to illustration FVX325, TMX425 Series elevation actuator
Adjustment.)
19. Return to 0 incline.
20. Hit disconnect button.
21. Replace end cap and bolt on TMX425 Series.
FVX325 Series Elevation Chart
6-6
Remove actuator top cover.
Using a large (.375" wide) flat blade screw driver, rotate the lower switch
cam counterclockwise the proper amount to assure the treadmill will not
elevate past 25%.
Lower the value and raise it again to verify the treadmill dose not travel
past that point.
Return the box value to allow the treadmill to stop at 25% to complete the
grade calibration.
If the cam was turned to adjust the lower switch, the upper cam will need
to be reset to zero to allow the treadmill to park in the correct position.
This is achieved by turning the upper cam (by hand) clockwise back the
approximate amount the lower cam was turned.
Check tape measure reading and adjust upper cam to compensate for any
error.
Repeat steps 1 thru 9 until the correct values are achieved.
FVX, TMX Series Service Manual
TRACKMASTER
Dim.
Grade
Inches
A
0%
3.04"
B
.5%
3.32"
C
5%
5.62"
D
10%
8.42"
E
15%
11.20"
F
20%
13.48"
G
25%
15.84"
MM
[77.3mm]
[84.3mm]
[142.8mm]
[223.8mm]
[284.5mm]
[342.4mm]
[402.4mm]