TRACKMASTER
ESB Circuit Fault Isolation Instructions
FVX, TMX No Control
FG302 P/S
Emergency Stop
J4
J5
ESB SW – N/C
1. Use Ohm Meter to test continuity from
FG302 J4 to J5 with the switch in the up
position.
2. Isolate and repair any breaks found in
circuit
August, 2006
FVX, TMX Manual Control
FG 310 Controller
PCB
J10
1. Use Ohm Meter to test continuity from
FG310 J9 to J10 with the switch in the
up position.
2. Isolate and repair any breaks found in
circuit
FVX, TMX Programmable Control
FG 311 Controller
PCB
1. Use Ohm Meter to test continuity
from FG3111 J2 to J3 with the switch
in the up position.
2. Isolate and repair any breaks found
in circuit
FVX, TMX Series Service Manual
Emergency Stop
J9
ESB SW – N/C
Emergency
J2
J3
ESB SW – N/C
St
14-17