Inverter Parameters/Software Version 403
Pass code 225(initial), after setting 135
Values that are different from factory specifications are in bold Italic.
NO.
PARAMETER NAME
01
LINE VOLTAGE
02
CARRIER
FREQUENCY
03
START METHOD
04
STOP METHOD
05
STANDARD SPEED
SOURCE
06
RELAY OUTPUT
10
TB-13A FUNCTION
SELECT
11
TB-13B FUNCTION
SELECT
12
TB-13E FUNCTION
SELECT
TB-13E OUTPUT
SELECTIONS
OTHER SELECTIONS
14
CONTROL
11-8
RANGE OF ADJUSTMENT
HIGH (01), LOW (02)
4kHz (01), 6 kHz (02), 8 kHz (08), 10 kHz (04) 6 kHz (05)
NORMAL (01), START ON POWER UP (02),
START WITH DC BRAKE (03), AUTO
RESTART WITH DC BRAKE (04), FLYING
RESTART 1 (05), FLYING RESTART 2 (06),
FLYING RESTART 3 (07)
COAST (01), COAST WITH DC BRAKE (02),
RAMP (03), RAMP WITH DC BRAKE (04)
KEYPAD (01), PRESET #1 (02), 0-10 VDC
(03), 4-20 mA (04)
NONE (01), RUN (02), FAULT (03), INVERSE
FAULT (04), FAULT LOCKOUT (05). AT SET
SPEED (06), ABOVE PRESET #3 (07).
CURRENT LIMIT (08), AUTO SPEED (09).
REVERSE (10)
NONE (01), 0-10 VDC (02), 4-20 mA (03).
PRESET SPEED #1 (04), RUN REVERSE (05),
START REVERSE (06), EXTERNAL FAULT (07),
REMOTE KEYPAD (08), DB FAULT (09),
AUXILIARY STOP (10), ACCEL/DECEL #2 (11)
NONE (01), 0-10 VDC (02), 4-20 mA (03),
PRESET SPEED #2 (04), DECREASE FREQ (05),
START FORWARD (06), JOG FORWARD (07),
JOG REVERSE (08), EXTERNAL FAULT (09),
INVERSE EXT FAULT (10) AUXILIARY STOP
(11), ACCEL/DECEL #2 (12), REMOTE
KEYPAD (13)
NONE (01), 0-10 VDC (02), 4-20 mA (03).
PRESET SPEED #3 (04), INCREASE FREQ (05),
START FORWARD (06), EXTERNAL FAULT
(07), INVERSE EXT FAULT (08), AUXILIARY
STOP (09), ACCEL/DECEL #2 (10)
RUN (11), FAULT (12), INVERSE FAULT (13),
LOCKOUT (14), AT SET SPEED (15), ABOVE
PRESET#3 (16), CURRENT LIMIT (17), AUTO
SPEED (18), REVERSE (19), DYNAMIC
BRAKING (20)
REMOTE KEYPAD (21)
TERMINAL STRIP ONLY (01), REMOTE
KEYPAD ONLY (02).
FVX, TMX Series Service Manual
TRACKMASTER
FACTORY
DEFAULT
HIGH (01)
NORMAL (01)
COAST (01)
KEYPAD (03)
NONE (01)
NONE (01)
NONE (01)
NONE (01)
TERMINAL
STRIP ONLY
(01)
August, 2006