Trackmaster FVX325 Field Service Manual page 56

Table of Contents

Advertisement

TRACKMASTER
Advance to next test by pressing YES.
Warning: Pressing the STOP switch will skip Grade Test and start the Belt Motor Test.
Observe Message Center Display
and Distance window. >
Pressing the INCLINE UP switch elevates the treadmill.
As the treadmill elevates the value in the DISTANCE
window increases. The value in the DISTANCE window
is the output of the elevation sensor as read by the control console.
Pressing the INCLINE DOWN switch will lower the
DISTANCE
treadmill and the value in the DISTANCE window should decrease.
WARNING: Prior to starting the Belt Motor Test, remove all items from the running belt
and stand clear of the running belt during test.
Advance to next test by pressing STOP.
Motor Test
Observe Message Center, Incline,
Speed, Time, and Distance windows. >
50 is the PWM sent from the control console to the FG309 P/S board to set speed. 3175 is the roller
ratio. Value is factory set. Value in the Time window is the output of the speed sensor as read by the
control console. Value is displayed in MPH.
Press SPEED UP arrow to increase PWM. An increase in PWM will cause an increase in the belt
speed.
Pressing INCLINE UP / INCLINE DOWN will increase or decrease the roller ratio.
INCLINE
SPEED
DISTANCE
TIME
Press STOP to end Belt Motor Test and advance to the next test.
5-25
August, 2006
FVX, TMX Series Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmx435Fvx325cTmx425cpFvx325cpTmx425c

Table of Contents