Trackmaster FVX325 Field Service Manual page 62

Table of Contents

Advertisement

TRACKMASTER
16.
Press Stop + Enter for SPD CAL will appear in the Message Center. This function
is used to calibrate speed. Press and hold ENTER key and the STOP key
simultaneously. Automatic Calibration Clear Belt then press Start will appear in
the Message Center. Press START key. When the treadmill has completed this
process, the Message Center will read Calibration Complete Press A key. If
calibration fails, Calibration Failed will appear in the Message Center. See trouble
shooting procedures for Speed Calibration Failed. Press ENTER key.
Controller
Action Required
Display
Press Stop
Press and hold
+ Enter for
Enter key and
SPD CAL
Stop key
simultaneously
to enter Speed
Calibration
Mode
17.
Press Stop + Enter for GRD CAL will appear in the Message Center. This
function is used to reset the elevation grades. Press STOP +ENTER key for
calibration. Refer to Elevation Calibration Procedure. Press ENTER key to skip and
go into normal workout mode. Refer to FVX325, TMX425 Series Elevation Charts.
Controller
Action Required
Display
Press Stop
Press and hold
+ Enter for
Enter key and
GRD CAL
Stop key
simultaneously to
enter Elevation
Calibration Mode
FVX325 Series Elevation Chart
August, 2006
Changes Affect
Adjusts speed
accuracy at all
speed ranges;
low, medium,
and high speeds
Changes Affect
Adjusts
elevation %
accuracy at all
ranges
FVX, TMX Series Service Manual
Parameter
Observe
Options
N/A
Press
Enter for GRD
CAL appears in
Message Center
Parameter
Observe
Options
N/A
Controller will
shortly flash reset
phase (Figure 1-1)
followed by
software version
phase (Figure 1-2)
and finally idle
phase (Figure 1-3).
Dim.
Grade
Inches
A
0%
3.04"
B
.5%
3.32"
C
5%
5.62"
D
10%
8.42"
E
15%
11.20"
F
20%
13.48"
G
25%
15.84"
Stop
+
MM
[77.3mm]
[84.3mm]
[142.8mm]
[223.8mm]
[284.5mm]
[342.4mm]
[402.4mm]
5-31