Power Distribution Fault Isolation (1) 120VAC Instructions
1. Use ohmmeter, measure continuity from connectors of power indicator to output of C/E
filter. Repair break in wire or proceed to next step.
2. Measure continuity through C/E filter, replace C/E filter if defective or proceed to next step
3. Measure continuity from input of C/E filter to the output of treadmill 20amp Circuit Breaker
On/Off switch. Replace 20amp Circuit Breaker On/Off switch if defective or proceed to next
step
4. Measure continuity of power cord from input of power cord, C/E filter to the blades at
molded plug of power cord. Replace power cord if defective.
Power Distribution Fault Isolation (2) 208-240VAC Instruction
1. Use ohmmeter, measure continuity from connectors of power indicator to output of C/E
filter. Repair break in wire or proceed to next step.
2. Measure continuity through C/E filter, replace C/E filter if defective or proceed to next step
3. Measure continuity from input of C/E filter to the output of treadmill 15amp Circuit Breaker
On/Off switch. Replace 15amp Circuit Breaker On/Off switch if defective or proceed to next
step
4. Measure continuity of power cord from input of power cord, C/E filter to the blades at
molded plug of power cord. Replace power cord if defective.
Power Distribution Fault Isolator (3) 120VAC Instructions
1. Turn treadmill power switch off (0)
2. Use ohmmeter, measure continuity from Leeson Speedmaster Power Input L1 and N to
output of C/E filter. Identify and repair break in wire.
Power Distribution Fault Isolator (4) 208-240VAC Instructions
1. Turn treadmill power switch off (0)
2. Use ohmmeter, measure continuity from Leeson Speedmaster Power Input L1 and L2 to
output of C/E filter. Identify and repair break in wire.