Leeson Inverter Inspection Sheet - Trackmaster FVX325 Field Service Manual

Table of Contents

Advertisement

Leeson Inverter Inspection Sheet

Please complete and fax to 316-283-3350
Treadmill S/N
1. Measure Input Power
a. A/C
Measure the Inverter A/C Input voltage
under three conditions.
240 VAC measure from L1 to L2
120 VAC measure from L1 to N
Treadmill on, motor off
Motor running at minimum
speed, no load
Motor running at minimum
speed, with load
Table 1
b. D/C
Measure the D/C voltage under two
conditions.
Measure between Pins 1(Violet) and
2(black)
Treadmill on, motor off
Motor on at minimum
speed
Table 2
2. Inspect Fault History
Press the inverter Mode button 3 times; the
inverter readout displays existing fault codes.
Example 1LF indicates the first fault code is
LF, press the up arrow to observe additional
fault codes up to 8 maximum. Note all
existing fault codes. If there are no existing
fault codes the readout displays .-.
1.
5.
2.
6.
3.
7.
4.
8.
Table 3
11-2
Leeson S/N
Approx. Weight
of test load.
Lbs or Kg
FVX, TMX Series Service Manual
TRACKMASTER
Neutral
Hot
220VAC
110VAC
L1
L2
EPM
MODE
August, 2006
N
Pin 1 – Violet
Pin 2 – Black
Pin 5 – Gray
Pin 6 – Red
Pin 12-2 Jumper
Pin 2 - White