Trackmaster FVX325 Field Service Manual page 131

Table of Contents

Advertisement

14
CONTROL
15
SERIAL LINK
16
UNITS EDITING
17
ROTATION
19
ACCELERATION
TIME
20
DECELERATION
TIME
21
DC BRAKE TIME
22
DC BRAKE VOLTAGE 0.0 - 30.0 %
23
MINIMUM
FREQUENCY
24
MAXIMUM
FREQUENCY
25
CURRENT LIMIT
26
MOTOR OVERLOAD
27
BASE FREQUENCY
28
FIXED BOOST
29
ACCEL BOOST
30
SLIP COMPLETION
31-
PRESET SPEEDS
37
38
SKIP BANDWIDTH
39
SPEED SCALING
40
FREQUENCY
SCALING
41
LOAD SCALING
42
ACCEL/DECEL #2
43
SERIAL ADDRESS
44
PASSWORD
47
CLEAR HISTORY
11-4
TERMINAL STRIP ONLY (01) . REMOTE
KEYPAD ONLY (02). TERMINAL STRIP
OR REMOTE KEYPAD (03)
DISABLE (01),
9600, 8, N, 2 WITH TIMER (02)
9600, 8, N, 2 WITHOUT TIMER (03)
9600, 8, E, 1 WITH TIMER (04)
9600, 8, E, 1 WITHOUT TIMER (05)
9600, 8, 0, 1 WITH TIMER (06)
9600, 8, 0, 1 WITHOUT TIMER (07)
TENTHS OF UNITS (01),
WHOLE UNITS (02)
FORWARD ONLY (01),
FORWARD AND REVERSE (02)
0.1 -3600.0 SEC
0.1 - 3600.0 SEC
0.0 - 3600.0 SEC
0.0 - MAXIMUM FREQUENCY
MINIMUM FREQ. - 240.0 Hz ( NOTE 2)
30 - 180 % (NOTE 3)
30 - 100%
25.0 - 500.0 Hz ( NOTE 4)
0.0 - 30.0 %
0.0 - 20.0 %
0.0 - 5.0 %
0.0 MAXIMUM FREQUENCY
0.0 - 10 Hz
0.0 - 6500.0
3.0 - 2000.0 Hz
10 - 200%
0.1 - 3600.0 SEC
1- 247
000 - 999
MAINTAIN (01), CLEAR (02)
FVX, TMX Series Service Manual
TRACKMASTER
TERMINAL STRIP
ONLY (01)
9600, 8, N, 2
WITH TIMER (02)
WHOLE UNITS (02)
FORWARD ONLY (01)
8.0 SEC
10.0 SEC
0.0 SEC
0.0 %
3.0 Hz
190.0 Hz (Reference)
180%
100%
60.0 Hz (NOTE 5)
4.0%
0.0 %
0.0%
0.0 Hz
0.0 Hz
0.0
190.0 Hz (Reference)
200%
20.0 SEC
1
135
MAINTAIN (01)