Power requirements

Grounding Instructions
This product is equipped with a three-wire ground-type plug. The plug will fit into only a
grounding-type outlet. This is a safety feature – do not disable the plug's third (grounding)
pin with an adapter! Contact a
the plug into your outlet, or (2) uncertain that the outlet is grounded and meets local codes.
Dedicated circuit
A dedicated circuit is a power outlet reserved for the exclusive use of your treadmill.
This requires a power line to be routed from the main breaker box or sub-panel to the
power outlet for the treadmill.
components.
NOTE: In 110V applications, a 20 AMP High Magnetic type circuit breaker is
required for use. This is to Prevent the breaker from being thrown by a temporary high
current draws when the treadmill is switched on. For Square D service box use Part
number Q0120HM. For GE Service Box use Part Number THQL1120HM. Contact your
distributor for further information regarding this type of breaker.
4-10
qualified electrician if you are either (1) unable to insert
The outlet should not be shared with any other
FVX, TMX Series Service Manual
TRACKMASTER
August, 2006