2-9.
ELECTRICAL
REQUIREMENTS
(CONT.)
2-10.
MOTOR BEARINGS
2-11.
LIGHTING AND
SHUTDOWN OF THE
BURNERS
2-12.
TESTING THE
FRYER
March 2014
To avoid electrical shock, do not disconnect the ground
(earth) plug. This fryer must be adequately and safely
grounded (earthed). Refer to local electrical codes for
correct grounding (earthing) procedures or in absence
of local codes, with The National Electrical Code, ANSI/
NFPA No. 70-(the current edition). In Canada, all electrical
connections are to be made in accordance with CSA C22.2,
Canadian Electrical Code Part 1, and/or local codes.
Disconnect power supply before a thorough cleaning or servicing the fryer.
The electric motor bearings are permanently lubricated. DO NOT
LUBRICATE.
1.
Turn the power switch to the OFF position.
2.
Wait at least 5 minutes and then turn power switch to the ON position.
3.
Press
button on the controls (left or right).
4.
The burner lights and operates in a Melt Cycle until the
shortening reaches a preset temperature.
5.
Once the display shows a product selection or a double
dashes, press the desired product button.
The fryer is equipped with a ignition spark module which has a
set ignition safety time (TSA) of 90 seconds.
To shutdown burner:
1. Press
button on the controls (left or right).
2. Turn the power switch to the OFF position.
NOTE: This turns off all vats.
Each Henny Penny open fryer was completely checked and tested
prior to shipment. However, it is good practice to check the unit for
proper operation.
10