6-1.
SPECIAL PROGRAM
MODE
(CONT.)
March 2014
Press and hold the
button for 5 seconds until "LEVEL 2"followed by,
"SP PROG" and "ENTER CODE" show in the display.
Enter code 1,2,3, and "SP-1 TEMP FORMAT" flashes in the displays.
If a bad code is entered, a tone sounds and "BAD CODE" shows
on the display. Wait a few seconds, the controls revert back to the
cook mode, and repeat the above steps.
To exit from the Special Program Mode at any time, press and
hold
Degrees Fahrenheit or Celsius (SP-1)
The left display flashes "SP-1 TEMP FORMAT". Press the ▲ or ▼
buttons to choose ºF or ºC.
Use ◄ button to go back to previous menu items
Press ► button when finished with the current Level 2 step
Language (SP-2)
Press ► button and "SP-2 LANGUAGE" flashes on the left display.
Press the ▲ or ▼ buttons to select the desired language.
System Initialization (SP-3)
Press ► button and "SP-3 DO SYSTEM INIT" flashes in left display,
along with "INIT" in right display. To reset the controls to factory
default settings, press and hold √ button and control counts down
"IN 3", "IN2", "IN 1". Once display shows "-INIT-" & *DONE* the
controls are reset to factory defaults.
Audio Volume (SP-4)
Press ► button and "SP-4 VOLUME" flashes in the left display.
Press the ▲ or ▼ , or use product buttons, to adjust the volume of the
speaker, 10 being the maximum value and 1 the minimum.
Audio Tone (SP-5)
Press ► button and "SP-5" and "TONE" flash in the left display.
Press the ▲ or ▼ , or use product buttons, to adjust the tone of the
speaker, 2000 being the maximum value and 50 the minimum.