7-2.
ERROR CODES
(CONT.)
DISPLAY
"E-20-A"
•
Pressure Switch
"FAN SENSOR
failure
STUCK
•
Wiring problem
•
I/O board failure
CLOSED"
•
Pressure switch
"E-20-B"
"NO DRAFT"
failure/ hose loose
"CHECK FAN"
•
Draft fan failure/ low
voltage
•
Flue or hood
obstruction
•
Failure to ignite/ no
"E-20-D"
IGNITION
flame sense
FAILURE"
•
Slow heat recovery
"E-21"
•
Burner not igniting
"E-22"
"NO HEAT"
"CHECK GAS
VALVE"
•
Programming failure •
"E-41 " / "E-46"
•
Analog converter
"E-47"
chip or 12 volt
supply failure
•
Input system error
"E-48"
•
Temperature input
"E-54-C"
error
•
AIF PC board not
"E-60"
"FILTER IN USE"
communicating with
control PC board
•
Drain valve jumper
"E-70C"
wire missing or
disconnected
•
Pressure too high
"E-83-A"
•
Pressure too high
"E-83-B"
March 2014
CAUSE
•
If fan is not running, have pressure switch checked;
should be open circuit if no air pressure
•
If fan is running, wiring error, or relay on I/O board
closed
•
Press power button to vat off and back on again, if
E-20-B persists, have pressure switch checked; should
be open circuit if no air pressure; make sure hose is
connected to fan and pressure switch
•
Have draft fan checked; low voltage going to fan
•
Check the fryer flue and hood system for obstructions
•
Press power button to vat off and back on again, if
E-20-D persists, check gas line connections; check
gas shut-off valve; have ignition module checked; gas
valve checked; flame sensor gap checked; gas valve and
ignition module wiring checked
•
Have a certified service technician check the fryer for
correct voltage to the unit; have heat circuit checked;
have unit checked for loose or burnt wire
•
Have gas valve and heat circuit checked
Press power button to vat off and back on again, if any
of the error codes, have the controls re-initialized; if
error code persists, have the control board replaced
•
Press power button to vat off and back on again, if
"E-47" persists, have the I/O board, or the PC board
replaced; if speaker tones are quiet, probably I/O board
failure; have the I/O board replaced
•
Have PC board replaced
•
Turn switch to OFF, then back to ON; have control PC
board replaced if "E-54C" persists
•
Press power button to turn vat off, wait 15 seconds, and
turn back on again. If "E-60" persists, have connector
between the PC boards checked; replace AIF PC board
or control PC board, if necessary
•
Have the jumper wire checked on the PC board at drain
switch interlock position
•
Check filter system in Vat #1
•
Check filter system in Vat #2
75
CORRECTION