7-2.
ERROR CODES
(CONT.)
DISPLAY
"E-20-A"
Pressure Switch
"FAN SENSOR
failure
STUCK
Wiring problem
I/O board failure
CLOSED"
Pressure switch
"E-20-B"
"NO DRAFT"
failure/ hose loose
"CHECK FAN"
Draft fan failure/ low
voltage
Flue or hood
obstruction
Failure to ignite/ no
"E-20-D"
IGNITION
flame sense
FAILURE"
Slow heat recovery
"E-21"
Burner not igniting
"E-22"
"NO HEAT"
"CHECK GAS
VALVE"
Programming failure •
"E-41 " / "E-46"
Analog converter
"E-47"
chip or 12 volt
supply failure
Input system error
"E-48"
Temperature input
"E-54-C"
error
AIF PC board not
"E-60"
"FILTER IN USE"
communicating with
control PC board
Drain valve jumper
"E-70C"
wire missing or
disconnected
Pressure too high
"E-83-A"
Pressure too high
"E-83-B"
March 2014
CAUSE
If fan is not running, have pressure switch checked;
should be open circuit if no air pressure
If fan is running, wiring error, or relay on I/O board
closed
Press power button to vat off and back on again, if
E-20-B persists, have pressure switch checked; should
be open circuit if no air pressure; make sure hose is
connected to fan and pressure switch
Have draft fan checked; low voltage going to fan
Check the fryer flue and hood system for obstructions
Press power button to vat off and back on again, if
E-20-D persists, check gas line connections; check
gas shut-off valve; have ignition module checked; gas
valve checked; flame sensor gap checked; gas valve and
ignition module wiring checked
Have a certified service technician check the fryer for
correct voltage to the unit; have heat circuit checked;
have unit checked for loose or burnt wire
Have gas valve and heat circuit checked
Press power button to vat off and back on again, if any
of the error codes, have the controls re-initialized; if
error code persists, have the control board replaced
Press power button to vat off and back on again, if
"E-47" persists, have the I/O board, or the PC board
replaced; if speaker tones are quiet, probably I/O board
failure; have the I/O board replaced
Have PC board replaced
Turn switch to OFF, then back to ON; have control PC
board replaced if "E-54C" persists
Press power button to turn vat off, wait 15 seconds, and
turn back on again. If "E-60" persists, have connector
between the PC boards checked; replace AIF PC board
or control PC board, if necessary
Have the jumper wire checked on the PC board at drain
switch interlock position
Check filter system in Vat #1
Check filter system in Vat #2