3-2.

SET-UP MODE

March 2014
Upon initial start-up, the controls will ask to confirm the settings for
the fryer.
When main power switch is turned on, "OFF" shows in both
displays. Press
on either side and *SETUP* *ENTER CODE*
shows in display. Press 1, 2, 3, and "LANGUAGE" shows on the
left display, "ENGLISH" on the right display.
Use ▲ or ▼ buttons to change the operation display to:
Greek "EΛΛHNIKA", Russian "РУССКИИ", Swedish
"SVENSKA", German "DEUTSCHE", Portuguese "PORTUG.",
Spanish "ESPANOL", or French "FRANCAIS".
Press ► to continue with the other set-up items which include:
TEMP FORMAT -
F or
o
TIME FORMAT - 12-HR or 24-HR
ENTER TIME - Time of day (use product buttons to change)
ENTER TIME - AM or PM
DATE FORMAT - MM-DD-YY or DD-MM-YY
ENTER DATE - Today's date (use product buttons to change)
DAYLIGHT SAVING TIME - 1.OFF; 2.US (2007 & after);
3.EURO; 4.FSA (US before 2007)
FRYER TYPE - ELEC or GAS
VAT TYPE - FULL OR SPLIT
AUTOLIFT ENABLED? - NO LIFT or YES LIFT
BULK OIL SUPPLY - YES or NO
BULK OIL DISPOSE? - YES or NO
S/N - Shows serial number of the unit or can be recorded (THIS
SERIAL NUMBER SHOULD MATCH THE SERIAL
NUMBER ON THE DATA PLATE, ON THE DOORS.)
2nd LANGUAGE - By setting a second language in the controls,
2 languages can now be easily chosen by pressing
normal operation. One language shows in left display and
second language shows in right display. Pressing the √ button
under desired language, selects that language seen in displays.
2nd VOLUME - By setting a second volume in the controls,
2 volumes can now be easily chosen by pressing
during normal operation. One volume setting shows in left
display (NONE to 10; 10 being the loudest) and a second
volume shows in right display. To select volume, press √ button
under desired volume.
SETUP COMPLETE - OFF is displayed and unit shuts down.
Unless otherwise indicated, use ▲ or ▼ to change settings.
Setup Mode can also be accessed by re-initializing the controls, in Special
Program Mode, in Level 2 programming (SP-3).