6-2.

DO NOT DISTURB

March 2014
Time periods of peak operations during which the "FILTER NOW?"
message will not appear, may be programmed into the fryer. There are
three groupings of days - Monday thru Friday (M-F), Saturday (SAT),
and Sunday (SUN). Within each day grouping, up to 4 time periods
(M-F 1 thru M-F 4, SAT 1 thru SAT 4, and SUN 1 thru SUN 4) may be
programmed. A time period may be anywhere from 1 to 180 minutes in
length.
Press and hold the
1.
followed by, "SP PROG" and "ENTER CODE" show in the display.
Press
button once more and "DO NOT DISTURB" and
2.
"ENTER CODE" flash in the left display.
Enter code 1, 2, 3 (first 3 product buttons).
3.
"DO NOT DISTURB ENABLED?" flashes in the left display and
4.
YES or NO appears in the right display. Press the ▲or ▼ buttons to
choose YES or NO.
.
Press
button and "M-F 1" shows in the left display and the
5.
time flashes in the right display. Press the ▲ or ▼, or use product
buttons, to change the time.
Press
button and "M-F 1" shows in the left display and "A" or
6.
"P" flashes in the right display. Use the ▲ or ▼ buttons to choose
AM or PM.
Press
button and "M-F 1" shows in left display and far right
7.
character display flashes. Press product buttons to enter amount of
time (up to 180 minutes) during which filtering will be inhibited,
after time entered in step 5.
Press
button to move to the next timer period, M-F 2.
8.
Repeat steps 5, 6, 7, and 8 for other desired time periods.
9.
70