Typical braking resistors for A housing COMBIVERT F5 motor controls
F5 Size 230V Class
05
07.BR.100-1180
07
07.BR.100-1180
PD = continuous power disapation in watts, P6 = peak repetitive power disapation with a
sec on time and 120 sec cycle time. KEB can offer many types of braking resistors, please
contact your sale representative for more information.
Braking resistor connection with high temperature drive fault
• The resistor has a PTC type sensor and is connected to the T1, T2
terminal on the COMBIVERT F5. If a motor temperature sensor is used
it should be placed in series with the sensor of the braking resistor.
Note: if the braking transistor in the unit fails, there is no guarantee the
voltage to the resistor will be shut off!
Braking resistors can develop very high surface
temperatures, therefore install away from other
devices, above the motor control and where people
can not inadvertantly come in contact with it.
14
Ohms PD
P6
180
44
800
180
44
800
����
�������������
��
��
������
6
��
��
��