KEB COMBIVERT F5 series Installation Manual & Operation Manual page 26

1/2 - 1hp 230v
Hide thumbs Also See for COMBIVERT F5 series:
Table of Contents

Advertisement

Special Adjustments
Carrier frequency
Fixed frequencies
1...3
Input I1
Input I2
Input I1 and I2
26
The frequency with which the power modules are switched can be changed
depending on the application. The employed power stage determines the
maximum switching frequency as well as the factory setting. Generally,
the inverter can operate at frequencies higher than the rated value but not
under continuous load.
Low Switching Frequency
Lower inverter heating
Lower High Freq. ground current
Reduced power loss
Lower radio interferences
Reduced cogging at low speed
Adjustment range :
Resolution:
Factory setting:
(depending on power circuit)
Note:
At switching frequencies above 4 kHz pay absolute attention to the
max. motor cable length especially when using shielded cables.
Three fixed frequencies can be adjusted. The fixed frequencies are selected
with the inputs I1 (terminal 10), I2 (terminal 11) and I1 + I2.
Adjustment range:
Resolution:
Factory setting, CP.19:
Factory setting, CP.20:
Factory setting, CP.21:
If the adjusted values are outside of the fixed limits of CP.10 and CP.11,
then the actual run frequency is internally limited to the values of CP.10
and CP.11. The negative rotation values (i.e. -50Hz) are only available in
the "application mode". The rotation source of the fixed frequencies is not
changed by CP.34, it always corresponds to CP.34 = 2 (Fwd/Rev direction
selectable by terminal 14 or 15).
High Switching Frequency
Less audible noise produced
Improved sine-wave simulation
Less motor losses
2/4/8/12/16 kHz
1
_
Enter-Parameter
-400...400 Hz
0.0125 Hz
5 Hz
50 Hz
70 Hz