Special Adjustments
AN1 Interface
selection
Set value
0-limited
(Value 2 and 4)
-100%
-10V
Set value
absolute
(Value 3 and 5)
-100%
-10V
Adjustment range:
Resolution:
Factory setting:
Note:
The analog input 1 (AN1) can accept different types of signals. In order to
correctly evaluate the signal, this parameter must be adjusted to match the
signal source.
Value
Analog reference signal
0
0...±10 V DC, Rin=56 kOhm
1
0...± 20 mA DC, Rin=250 Ohm
2
4...20 mA DC, Rin=250 Ohm
Adjustment range:
Resolution:
Factory setting:
Note:
internal
intern
10V
100%
external
extern
100%
-100%
internal
intern
100%
10V
external
extern
100%
-100%
Enter-Parameter
Enter-Parameter
0...9
1
2
�����
�����
��
����
����
0...2
1
0
���
���
�����
�����