Verifying And Monitoring Sip Inspection - Cisco FirePOWER ASA 5500 series Configuration Manual

Security appliance command line
Hide thumbs Also See for FirePOWER ASA 5500 series:
Table of Contents

Advertisement

Chapter 25
Configuring Application Layer Protocol Inspection
This command configures the idle timeout after which a SIP control connection is closed.
To configure the timeout for the SIP media connection, enter the following command:
hostname(config)# timeout sip_media hh:mm:ss
This command configures the idle timeout after which a SIP media connection is closed.

Verifying and Monitoring SIP Inspection

The show sip command assists in troubleshooting SIP inspection engine issues and is described with the
inspect protocol sip udp 5060 command. The show timeout sip command displays the timeout value
of the designated protocol.
The show sip command displays information for SIP sessions established across the security appliance.
Along with the debug sip and show local-host commands, this command is used for troubleshooting
SIP inspection engine issues.
We recommend that you configure the pager command before entering the show sip command. If there
Note
are a lot of SIP session records and the pager command is not configured, it takes a while for the show
sip command output to reach its end.
The following is sample output from the show sip command:
hostname# show sip
Total: 2
call-id c3943000-960ca-2e43-228f@10.130.56.44
call-id c3943000-860ca-7e1f-11f7@10.130.56.45
This sample shows two active SIP sessions on the security appliance (as shown in the Total field). Each
call-id represents a call.
The first session, with the call-id c3943000-960ca-2e43-228f@10.130.56.44, is in the state Call Init,
which means the session is still in call setup. Call setup is not complete until a final response to the call
has been received. For instance, the caller has already sent the INVITE, and maybe received a 100
Response, but has not yet seen the 200 OK, so the call setup is not complete yet. Any non-1xx response
message is considered a final response. This session has been idle for 1 second.
The second session is in the state Active, in which call setup is complete and the endpoints are
exchanging media. This session has been idle for 6 seconds.
Skinny (SCCP) Inspection
This section describes SCCP application inspection. This section includes the following topics:
OL-10088-01
state Call init, idle 0:00:01
state Active, idle 0:00:06
SCCP Inspection Overview, page 25-68
Supporting Cisco IP Phones, page 25-68
Restrictions and Limitations, page 25-68
Verifying and Monitoring SCCP Inspection, page 25-69
Cisco Security Appliance Command Line Configuration Guide
Skinny (SCCP) Inspection
25-67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pix 500 seriesCisco asa 5500 series