2.6.11
Parameter Assignment for the Count Modes
Introduction
You can use either of the following to assign parameters for the 1Count24V/100kHz:
• A GSD file (http://www.ad.siemens.de/csi/gsd)
• STEP 7 V5.3 SP2 or later
Parameter List for Counting Modes
Table 2-8
Parameter List for Counting Modes
Parameter
Enable
Group diagnostics
Behavior in the event of the parent controller failing
Behavior at CPU/Master-STOP
Encoder parameters
Signal evaluation A, B
Encoder and input filter
At count input (track A)
•
At direction input (track B)
•
At digital input DI
•
Sensor A, B, DI
Direction input B
Output parameters
Function DO1
Function DO2
Substitute value DO1
Diagnostics DO1
1
Hysteresis DO1, DO2
Pulse duration [2 ms] DO1, DO2
Technological Functions
Operating Instructions, 02/2007, A5E00124867-05
Value range
Disable/enable
Turn off DO1/
Continue working mode/
DO1 substitute a value/
DO1 keep last value
Pulse and direction/
Rotary encoder single/
double/
quadruple
2.5 µs/25 µs
•
2.5 µs/25 µs
•
2.5 µs/25 µs
•
24V P switch, normal mode/
24V M switch
Normal/Inverted
Output/
Switch on at count ≥ comparison value/
Switch on at count ≤ comparison value/
Pulse on reaching the comparison value/
Switch at comparison values
Output/
Switch on at count ≥ comparison value/
Switch on at count ≤ comparison value/
Pulse on reaching the comparison value
0/1
Off/on
0...255
0...255
1Count24V/100kHz
2.6 Count Modes
Default
Disable
Turn off DO1
Pulse and direction
2.5 µs
•
2.5 µs
•
2.5 µs
•
24V P switch, normal
mode
Normal
Output
Output
0
Off
0
0