2PULSE
5.4 Application Examples
Programming/Flow Diagram
Below you will find a section from a STEP 7 STL program.
The configured start address of the inputs and outputs of the 2PULSE is 256.
You use this part of the program to start the filling process. To do this, memory marker
M30.0 must be set.
The pulse duration in this example is 5000 ms.
STL
Block:
PIB256
L
MB20
T
5000
L
PQW256
T
0
L
MB10
T
M20.2
U
M30.0
U
M10.0
=
MB10
L
PQB258
T
Wiring/Terminal Assignment Diagram
Figure 5-18
294
Description
Read the feedback messages from channel 0 of the 2PULSE
Write a pulse duration of 5000 ms to channel 0 of the 2PULSE
Generate SW_ENABLE
Container is positioned
Start of the filling process
Set SW_ENABLE=1
Write control signals to channel 0 of the 2PULSE
Terminal Assignment of the 2PULSE for Filling Liquids
Technological Functions