2PULSE
5.4 Application Examples
Parameters
The following parameters are required for channel 0 of the 2PULSE to pack piece goods in
pulse train mode.
Table 5-3
Parameter
Group diagnostics
Diagnostics DO 0
Behavior at CPU/Master-STOP
Mode
Time base
Function DI 0
On-delay
Minimum pulse duration
Period
The additional parameters of channel 0 of the 2PULSE have no effect on pulse train mode.
The parameters for channel 1 are not relevant in this application example.
302
Parameter List for the Packing of Piece Goods
Set Value
Enable
On
Turn off DO 0
Pulse train
1 ms
HW enable
0
500
1000
Meaning
The following errors trigger a
diagnostic message:
Short circuit of digital output
•
Short circuit of the encoder
•
supply
Parameter assignment error
•
The 2PULSE detects the short
circuit error on the digital output
DO 0.
All the preset times are
specified at a resolution of 1 ms.
The pusher is controlled
immediately with the software
enable.
This is 500 ms in the selected
time base
This is 1 s in the selected time
base. This results in an
interpulse period of 500 ms.
Technological Functions