1Count24V/100kHz
2.6 Count Modes
Address
Byte 5
C_DOPARAM
CMP_VAL2
CMP_VAL1
LOAD_PREPARE
LOAD_VAL
Bytes 6 to 7
Not used for modified user interface
1
Notes on the Control Bits
Table 2-5
Notes on the Control Bits
Control bits
Notes
C_DOPARAM
Change function and behavior of DO1, DO2 (see figure below)
The values from bytes 0 to 2 are applied as new function, hysteresis, and pulse duration of DO1,
DO2. This may result in the following error: The conditions for the "Switch at comparison values"
behavior are not fulfilled.
CMP_VAL1
Load comparison value 1 (see figure below)
The value from bytes 0 to 3 is transferred to comparison value 1 with the control bit "Load
comparison value CMP_VAL1".
CMP_VAL2
Load comparison value 2 (see figure below)
The value from bytes 0 to 3 is transferred to comparison value 2 with the control bit "Load
comparison value CMP_VAL2".
CTRL_DO1
Enable DO1
You use this bit to enable the DO1 output.
CTRL_DO2
Enable DO2
You use this bit to enable the DO2 output.
CTRL_SYN
You use this bit to enable synchronization.
EXTF_ACK
Error acknowledgment
The error bits must be acknowledged with the EXTF_ACK control bit after the cause is removed. (see
figure below)
LOAD_PREPARE
Load counter preparatory (see figure below)
The value from bytes 0 to 3 is applied as the load value.
LOAD_VAL
The value from bytes 0 to 3 is loaded directly as the new counter value (see figure below).
RES_STS
Start resetting of status bit
The status bits are reset through the acknowledgment process between the RES_STS bit and the
RES_STS_A bit. (see figure below)
SET_DO1
Control bit DO1
Switches the DO1 digital output on and off when CTRL_DO1 is set.
SET_DO2
Control bit DO2
Switches the DO2 digital output on and off when CTRL_DO2 is set.
SW_GATE
SW gate control bit
The SW gate is opened/closed via the control interface with the SW_GATE bit.
48
Assignment
Bit 7:
Reserve = 0
Bit 6:
Reserve = 0
Bit 5:
Reserve = 0
Bit 4:
Change function and behavior of DO1, DO2
Bit 3:
Load comparison value 2
Bit 2:
Load comparison value 1
Bit 1:
Load counter preparatory
Bit 0:
Load counter direct
Reserve = 0