Goodrive200 inverters
Fault code
Fault type
PIDE
PID feedback fault
bCE
Braking unit fault
Grounding
ETH1
shortcut fault 1
Grounding
ETH2
shortcut fault 2
Velocity deviation
dEu
Possible cause
 PID feedback offline
 PID feedback source
disappear
 Braking circuit fault or
damage to the braking
pipes
 The external braking
resistor is not sufficient
 The output of the inverter
is short circuited with the
ground
 There is fault in the current
detection circuit
 The actual motor power
sharply differs from the
inverter power
 The output of the inverter
is short circuited with the
ground
 There is fault in the current
detection circuit
 The actual motor power
sharply differs from the
inverter power
 The load is too heavy or
fault
stalled
 Check the PID feedback
 Check the PID feedback
 Check the braking unit and
 Increase the braking
 Check if the connection of
 Change the hoare
 Change the main control
 Set motor parameters
 Check if the connection of
 Change the hoare
 Change the main control
 Set motor parameters
 Check the load and
 Increase the detection
 Check whether the control
204
Fault tracking
What to do
signal
source
change new braking pipe
resistor
the motor is normal or not
panel
correctly
the motor is normal or not
panel
correctly
ensure it is normal
time
parameters are normal