Brocade Communications Systems FastIron SX 800 Diagnostic Manual page 46

Fastiron x series; fcx series; icx series; turboiron series;
Hide thumbs Also See for FastIron SX 800:
Table of Contents

Advertisement

3
MCT debug commands
Brocade# debug cluster mdup
CLUSTER MDUP: Send Vlan mask message to peer
CLUSTER MDUP: Received vlan mask from peer for cluster 1
mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 ) ->
mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 ),
port is CCEP
mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 ),
port is CCEP -> macmgr_move_mct_mac_from_icl_to_ccep
CLUSTER MDUP: Moving MACs from ICL port to CCEP port 3/13 for client 2668 in VLAN
100
mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 )
DONE
mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 ) ->
mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 ),
port is CCEP
mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 ),
port is CCEP -> macmgr_move_mct_mac_from_icl_to_ccep
CLUSTER MDUP: Moving MACs from ICL port to CCEP port 4/17 for client 3318 in VLAN
100
mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 )
DONE
<<<<< mdupmgr_sync_static_mac_table >>>
mdupmgr_sync_static_mac_table done, sync 0 entries
mdupmgr_sync_mac_table(restart=yes,ccp_up_restart=yes)(T=95629)
mac_mdup_sync_in_progress=0, start_mac_index=0, previous_loop_start_mac_index=0,
g_mac_mdup_sync_delay=0
mdupmgr_sync_mac_table(restart=yes,ccp_up_restart=yes)(T=95629) DELAY SYNC
(mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,
g_mac_mdup_sync_delay=2)&
CLUSTER MDUP: Convert CCR to CCL for cluster_id: 1, client rbridge id = 2668
macmgr_convert_ccr_to_ccl(cluster_id=1, port_id=3/13)(T=95629) client
A-satya-000000c74d40 (hw_timer_gone=1 msec)&
CLUSTER MDUP: Convert CCR to CCL for cluster_id: 1, client rbridge id = 3318
macmgr_convert_ccr_to_ccl(cluster_id=1, port_id=4/17)(T=95629) client
A-satya-000000147d80 (hw_timer_gone=1 msec)&
mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95630)
mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,
g_mac_mdup_sync_delay=2
mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95630) DELAY SYNC
(mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,
g_mac_mdup_sync_delay=3)&
mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95631)
mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,
g_mac_mdup_sync_delay=3
mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95631) DELAY SYNC
(mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,
g_mac_mdup_sync_delay=4)&
debug cluster show
Syntax: [no] debug cluster show
This command displays debug flags for the cluster as shown in the following example.
Brocade# debug cluster show
CLUSTER debugging is
CLUSTER ALL debugging is
CLUSTER IPC debugging is
CLUSTER Hardware debugging is
34
:ENABLED
:OFF
:OFF
:OFF
Brocade FastIron, FCX, ICX, and TurboIron Diagnostic Reference
53-1002965-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents