supportsave commands
The following is the sample output from the supportsave show command.
Brocade# supportsave show
Supportsave is executing commands: 19% completed
Brocade# supportsave show
Supportsave is executing commands: 34% completed
Brocade# supportsave show
Supportsave is executing commands: 60% completed
Brocade# supportsave show.
Supportsave is executing commands: 100% completed
Supportsave is transporting files...
supportsave add_cust_cmd index
Syntax: supportsave add_cust_cmd index index_number "cli string"
This command adds a run-time executable command into the custom module at a particular index
of 32 characters long (maximum of 32 characters are allowed) during the run time.
Brocade# supportsave add_cust_cmd index 1 "show chassis"
supportsave del_cust_cmd index
Syntax: supportsave del_cust_cmd index index_number
The index_number variable specifies the index of a command in the custom commands list that
needs to be removed. The valid range is from 1 through 32.
This command deletes a command from the custom module at a particular index during the run
time.
supportsave del_cust_cmd all
Syntax: supportsave del_cust_cmd all
This command deletes all the custom module commands.
supportsave list_cust_cmd
Syntax: supportsave list_cust_cmd
This command displays all commands present in the custom commands list.
supportsave info enable
Syntax: supportsave info enable
This command enables the header to be displayed for all show commands being executed on CLI.
182
show - Displays the progress of the log collection that has been executed on a terminal other
than the one on which the supportsave command is executed.
cancel - Cancels the current log collection that has been executed on a terminal other than the
one on which the supportsave command is executed.
index_number - Specifies the index in the custom commands list where an additional
command need to be added. The valid range is from 1 through 32.
cli string - Specifies the commands to be added to the custom commands list.