Specifications:
Note:
Siemens Milltronics makes every attempt to ensure the accuracy of these
specifications, but reserves the right to change them at any time.
Pointek CLS 200
Power
• 12 to 250 V AC/DC
• explosion proof
• auxiliary source
• separate supply necessary
Performance
Measurement frequency
Repeatability
Interface
• configuration
• local display
• output
• polarity-independent
• failsafe
Alarm Outputs
• relay
• solid-state switch
• time delay
Page I – 8
Pointek CLS 200 (analog) – INSTRUCTION MANUAL
analog model
2 VA/2 W max.
12 to 250 V AC/DC
2 VA/2 W max.
from power connector
no
5.5 MHz @ εr = 1
1.1 MHz @ εr = 80
±1% of measurement
locally, using dip switches and potentiometers
3 LED indicators
relay contact
and solid-state switch
yes
relay and solid-state switch can be de-energized in
the absence of a sensor signal
1 form C (SPDT) contact,
rated 8 A at 250 V AC/5 A at 30 V DC.
rated 250 V AC/300 V DC, 100 mA max.
ON/OFF alarm, selectable
1 to 60 seconds duration
7ML19985AR02