Chapter 7
Diagnosing Problems
Table 15. LCD Message Troubleshooting Table
Displayed Message
HMR BANK FAN
FLT
ILL EXT BUS ACC*
ILLGL OPR ACCSS*
INCOMPAT E-NET
INTAKE FAN FAULT
332
Can User
Explanation
Correct?
Yes
Sensors cannot
detect current in
fan circuit.
No
Fatal firmware
error on controller
board.
No
Fatal firmware
error on controller
board.
Yes
Incompatible
network interface
card (NIC) is
installed.
Yes
Sensors cannot
detect current in
fan circuit.
Solution
Check that fan cable is
connected. Check for
obstruction of vents and
fan airway; remove any
obstructions. Check for
items beneath the printer
blocking cabinet vents.
Power back on the
printer. If this message
recurs, contact your
authorized service
1
representative.
Contact your authorized
1
service representative.
Contact your authorized
1
service representative.
Install a compatible NIC
to the printer then reboot.
If this message still
appears, contact your
authorized service
1
representative.
See description for HMR
BANK FAN FLT.