Printronix P7000 User Manual page 143

Printronix printer user's manual
Hide thumbs Also See for P7000:
Table of Contents

Advertisement

Print Quality
Data Processing (default). The emulation prints at 60 x 72 dpi
and lets you choose between normal alphanumerics and
barcodes and dark mode alphanumerics and barcodes. This
mode should be set if you want the highest speed.
High. The emulation prints at 120 x 72 dpi, but all
alphanumerics and barcodes are automatically printed in dark
mode.
Best. The emulation prints at 120 x 144 dpi and dark mode,
which produces a higher resolution, better-looking print image.
Power-on S-Mode
This option instructs the PGL to behave similarly to older versions
of the IGP with respect to certain commands.
All new users with new applications should select "0," the default
option. Selecting this mode insures the printer will behave as
described in this manual.
Power on S-Mode sets the printer in an SMODE compatibility state
at power-up. The default is 0 (disabled, no power-on mode). To use
this feature, select a mode from 1 through 5, which puts IGP/PGL in
an SMODE state according to the compatibility mode set. If the
compatibility mode set is None, then MVP is assumed by default.
For more information, see the IGP/PGL Programmer's Reference
Manual.
Trunc Dyn Data
This submenu allows the user to truncate the dynamic data up to
the maximum data length specified in Create Mode.
Disable (the default). If the dynamic data exceeds the
maximum data length, an error will report.
Enable. If the dynamic data exceeds the maximum data length,
the data truncates.
IGP/PGL Submenu
IGP/PGL Submenu (with LG)
143

Advertisement

Table of Contents
loading

Table of Contents