Table 2-15. RTRV-COND Output Fields
Field
pwra
Indicates if the IMC has detected a loss of power at the Power A(B) connection. The
pwrb
possible returned values can be either PWRA(B)-OK (no PWRA(B) alarm is
currently active), or PWRA(B)-ALM (a PWRA(B) alarm is currently active).
expneqpt
Indicates if the connection to the expansion output panel was lost. The possible
returned values can be either EXP-OK (no EXPFAIL alarm is currently active), or
EXP-ALM (an EXPFAIL alarm is currently active).
extalm1
Indicates if external equipment is currently generating alarm(s). The possible
extalm2
returned values can be either EXT1(2)-OK (no EXTALM1(2) alarm is currently
active), or EXT1(2)-ALM (an EXTALM1(2) alarm is currently active).
ioc1eqpt
Indicates if the system is equipped with an IOC module in the specified slot. The
ioc2eqpt
possible returned values can be either IOC1(2)-EQPT (an IOC1(2)-EQPT event was
received), or IOC1(2)-UNEQPT (no IOC1(2)-EQPT event was received).
sysqlevel
Indicates the system output quality level (1 through 9)
lastdat
The date the system was last provisioned by a user. The format is YY-MM-DD.
lasttim
The time the system was last provisioned by a user. The format is HH:MM:SS.
ioc1comm
Indicates if an IOC1(2) communication alarm currently is active. The possible returned
ioc2comm
values can be either IOC1(2)COMM-OK (no IOC1(2)COMM alarm is currently active),
or IOC1(2)COMM-ALM (an IOC1(2)COMM alarm is currently active).
Note: The following status conditions are reported by the IOC modules, but are stored in the IMC.
When you issue the RTRV-COND command, the IMC reports the last status conditions it received
from the IOC modules. If a given IOC module is removed or develops a communication problem, the
status as reported by the IMC might not be accurate.
iocstatus
The current status of the specified IOC module. The status can be either OK (no IOC
alarms are currently active for the specified module), or ALM (one or more IOC
alarms are currently active for the specified module).
ioccomm
Indicates if a communication alarm from the IOC1(2) to the IOC2(1) module is
currently active. The returned values can be IOC1(2)TO2(1)COMM-OK
(no IOC1(2)TO2(1)COMM alarm is currently active), or IOC1(2)TO2(1)COMM-ALM
(an IOC1(2)TO2(1)COMM alarm is currently active).
imccomm
Indicates if a communication alarm from the IMC to the IOC2(1) module currently is
active. The returned values can be IMC1(2)COMM-OK (no IMC1(2)COMM alarm is
currently active), or IMC1(2)COMM-ALM (an IMC1(2)COMM alarm is currently
active).
097-58001-01 Revision E – September 2006
Chapter 2 TL1 Command Syntax and Description
Description
<aid> = SYS
<aid> = IMC
<aid> = IOC1 | IOC2
Retrieve Condition (RTRV-COND)
TimeProvider TL1 Reference Guide
89