Rtrv-Eqpt Output Field - Symmetricom TimeProvider 1100 Reference Manual

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Chapter 2 TL1 Command Syntax and Description
Retrieve Equipment (RTRV-EQPT)
Parameter
<aid>
cont'd
Normal Retrieve Response
<cr><lf><lf>
sid date time<cr><lf>
M
ctag COMPLD<cr><lf>
"<aid>:<keyword>,<value>"<cr><lf>
;
Table 2-18. RTRV-EQPT Output Field
Field
<aid>
<keyword>
<value>
Example
To display the current baud rate setting for the local serial communications (COML)
port:
Input
RTRV-EQPT::COML:TP1000::BAUD;
Response Example
TP-SSU 05-02-10 13:37:39
M
TP1000 COMPLD
"COML:BAUD,9600"
;
Autonomous Message
None
102 TimeProvider TL1 Reference Guide
Value
NTP
Equipment settings for the NTP:
Peer Server
Authentication
Note: See
<keywords> and descriptions of their possible <values>.
The access identifier for the equipment component (refer to
Equipment
(ED-EQPT), on page 45 for valid <aid>).
The specific equipment parameter being requested (refer to
Equipment
(ED-EQPT), on page 45 for valid <keyword>).
The current setting of the requested equipment parameter
Description
ED-EQPT for NTP
Parameters, on page 51 for
Description
097-58001-01 Revision E – September 2006
Edit
Edit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000