Retrieve Network Equipment Type (RTRV-NETYPE)

This command retrieves the network equipment (NE) type from the unit, in this
case, "TimeProvider."
This command has a default access level of NONE.
Syntax
RTRV-NETYPE:::[<ctag>];
Example
To retrieve the NE type from the TimeProvider:
Input
RTRV-NETYPE:::TP1000;
Normal Response
TP-SSU 05-02-10 13:37:39
M
TP1000 COMPLD
"TimeProvider"
;
Autonomous Message
None