Rtrv-Sync Output Field - Symmetricom TimeProvider 1100 Reference Manual

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Chapter 2 TL1 Command Syntax and Description
Retrieve Sync (RTRV-SYNC)
Normal Retrieve Response
<cr><lf><lf>
sid date time<cr><lf>
M
ctag COMPLD<cr><lf>
"<aid>:<keyword>,<value>"<cr><lf>
;
Table 2-29. RTRV-SYNC Output Field
Field
<aid>
<keyword>
<value>
Example
To retrieve the current priority setting for input reference 2:
Input
RTRV-SYNC::INP2:TP1000::PRIORITY;
Response Example
TP-SSU 05-02-10 13:37:39
M
TP1000 COMPLD
"INP2:PRIORITY,3"
;
Autonomous Message
None
124 TimeProvider TL1 Reference Guide
The access identifier for the equipment component (Refer to
(ED-SYNC), on page 55 for valid <aid>)
The specific equipment parameter being requested (Refer to
(ED-SYNC), on page 55 for valid <keyword>)
The current setting of the requested equipment parameter
Description