Symmetricom TimeProvider 1100 Reference Manual page 158

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Appendix C Events
Table C-1. Event Identifiers (Continued)
Event ID
or
Event Description
CONDTYPE
FLOW
The IMC serial port flow
control has changed
FWFAIL
The firmware upgrade of
IMC was unsuccessful.
The firmware upgrade of
the IOC was unsuccessful.
FWOK
The firmware upgrade of
IMC was successful. The
firmware upgrade of the
IOC was successful.
IMCBIST
The user has requested
the IMC to perform a
Built-in Self Test.
INACTTIME Set the communication
inactivity timeout. If no
user command is entered
within the specified time
the user's session is
terminated.
INITLOG
The event log has
initialized.
IPADDR
The IMC Ethernet
address has changed.
IPGATE
The IMC Ethernet gateway
address has changed.
IPSUB
The IMC Ethernet subnet
mask has changed.
ISDIFF
Indicates that the CRC of
two Istates images stored
on separate modules are
different.
ISEQ
Indicates that the CRC of
two Istate images stored
on separate modules are
equal.
158 TimeProvider TL1 Reference Guide
AID
Default Value
TYPE
EQPT NONE
EQPT NA
EQPT NA
EQPT NA
EQPT 0 (no timeout)
EQPT NA
EQPT 0.0.0.0
EQPT 0.0.0.0
EQPT 255.255.255.0
EQPT NA
EQPT NA
Value Description
NONE – No flow control
SW – Software flow control
XON/XOFF
HW – Hardware flow control
CTS/RTS
SWHW – Use both types of
flow control
NA
NA
PASSED – test(s) passed
FAILED – test(s) failed
0 = Disable timeout
100 to 10000 (seconds)
NA
1.0.0.1 to 254.255.255.254
1.0.0.1 to 254.255.255.254
1.0.0.1 to 254.255.255.254
NA
NA
097-58001-01 Revision E – September 2006

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents