Set Attribute (Set-Attr) - Symmetricom TimeProvider 1100 Reference Manual

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Set Attribute (SET-ATTR)

This command sets the alarm level that an event generates. Use this command also
to reset all alarm levels to factory settings, and to specify whether or not the system
escalates alarms.
This command has a default access level of ADMIN.
Syntax
SET-ATTR:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];
Parameter
<aid>
097-58001-01 Revision E – September 2006
Value
See
Table 2-32
SYS
The command's effect is at the system level.
IMC
Sets the alarm level for the specified Information Management
Card module alarm to the specified value.
IOCm
Sets the alarm level for the specified alarm in the specified
Input/Output Card module to the specified value.
m = "1" for the slot marked "IOC 1" on the main shelf
m = "2" for the slot marked "IOC 2" on the main shelf
GPS
Sets the alarm level for the GPS alarm to the specified value.
PRS
Sets the alarm level for the PRS alarm to the specified value.
OUTg
Sets the alarm level on the Output group specified by g:
g = "A" for the group marked "A" on the main shelf
g = "B" for the group marked "B" on the main shelf
g = "C" for the group marked "C" on the main shelf
g = "D" for the group marked "D" on the main shelf
INPp
Sets the alarm level for the alarm related to the specified input
port to the specified value.
p = "1" for the input marked INP 1 on the Input Connector
module
p = "2" for the input marked INP 2 on the Input Connector
module
RTMg
Sets the alarm level on the Retimer group specified by g:
g = "A" for the group marked "A" on the main shelf
g = "B" for the group marked "B" on the main shelf
g = "C" for the group marked "C" on the main shelf
g = "D" for the group marked "D" on the main shelf
E422g
Sets the alarm level on the EIA-422 output group specified by g:
g = "A" for the group marked "A" on the main shelf
g = "B" for the group marked "B" on the main shelf
g = "C" for the group marked "C" on the main shelf
g = "D" for the group marked "D" on the main shelf
Chapter 2 TL1 Command Syntax and Description
Description
for <keyword> and <value> descriptions.
TimeProvider TL1 Reference Guide 131
Set Attribute (SET-ATTR)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents