Chapter 2 TL1 Command Syntax and Description

Delete Performance Monitoring Data (DLT-PM-DATA)

Delete Performance Monitoring Data (DLT-PM-DATA)
This command deletes the current set of performance monitoring data for one input
channel. All Performance Data associated with the specified input is erased.
This command has a default access level of USER.
Syntax
DLT-PM-DATA:[<tid>]:[<aid>]:[<ctag>];
aid
IOC[m]-GPS
IOC[m]-PRS
IOC[m]-INP[p]
Example
To delete all performance data associated with the specified module:
Input
DLT-PM-DATA:::TP1000;
Normal Response
TP-SSU
M
TP1000 COMPLD
;
38
TimeProvider TL1 Reference Guide
GPS input on either of the two IOC modules (m = 1 or 2).
PRS input on either of the two IOC modules (m = 1 or 2).
Input 1 or Input 2 on either of the two IOC modules
(m = 1 or 2 and p = 1 or 2).