Chapter 2 TL1 Command Syntax and Description
Edit Sync (ED-SYNC)
Table 2-6. ED-SYNC – Keywords and Values
<keyword>
<value>
CLRDELAY
0 – 1000
FLTDELAY
1 – 15
REFMODE
AUTO
FORCED
INPREF
GPS
PRS
INP1
INP2
Note: When INPREF is used as a keyword with the RTRV-SYNC
command, the input that is currently selected as the system
reference is returned.
CCALIGN
NA
56
TimeProvider TL1 Reference Guide
Description
<aid> = SYS
The time, in seconds, that elapses after a signal fault
clears and before the associated alarm condition
clears. This delay helps prevent an alarm from
clearing before the signal is stable.
The time, in seconds, that elapses after an LOS, AIS,
or OOF fault occurs and before the associated alarm
condition is set. This delay helps prevent spurious
alarms.
The system automatically selects the reference input
based on the QLEVEL and PRIORITY settings.
Input reference selection is determined by the
INPREF parameter setting.
The GPS input is selected as the reference when
REFMODE=FORCED.
The PRS input is selected as the reference when
REFMODE=FORCED.
Input 1 is selected as the reference when
REFMODE=FORCED.
Input 2 is selected as the reference when
REFMODE=FORCED.
Allows the user to clear an INPTRR alarm against the
current reference by forcing the CC output into
polarity alignment with the reference. This is a
non-persistent value; when the alignment is
complete, the value returns to its previous value.
097-58001-01 Revision E – September 2006
Default
5
5
AUTO
PRS
NA

Hide quick links: