Rtrv-Log - Keywords For All <Aids; Rtrv-Log Event Output Fields - Symmetricom TimeProvider 1100 Reference Manual

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Chapter 2 TL1 Command Syntax and Description
Retrieve Log (RTRV-LOG)
Table 2-22. RTRV-LOG – Keywords for all <aids>
<keyword>
ALL (or null)
Retrieves both alarmed and non-alarmed events for the specified aid.
EVT
Retrieves non-alarmed events for the specified aid.
ALM
Retrieves alarmed events for the specified aid.
index
A specified value to skip that number of events before displaying data. 1 to 500
count
A specified value to retrieve that number of recent events or alarms.
start date
Start date of the event history to display
stop date
Stop date of the event history to display
Command Output
The following shows the event output format of the command and
explain the various fields in the output. The Alarm format follows this explanation of
events and
Table 2-24
Event Response Format
<cr><lf><lf>
sid date time<cr><lf>
alrmcde atag REPT EVT [AIDTYPE]<cr><lf>
"aid,aidtype:condtype,condeff,ocrdat,ocrtim,,,,:condscr"<cr lf>
"aid,aidtype:condtype,condeff,ocrdat,ocrtim,,,,:condscr"<cr lf>
.
.
"aid,aidtype:condtype,condeff,ocrdat,ocrtim,,,,:condscr"<cr lf>
;
Table 2-23. RTRV-LOG Event Output Fields
Field
aidtype
Specifies if the event is associated with the internal operation of the system (EQPT),
or external to the system or facility (T1).
ntfcncde
The notification code for the alarm or event. The notification code can be CR (critical
alarm), MJ (major alarm), MN (minor alarm), CL (clearing event), or NA
(non-alarmed event or report).
condtype
The TL1 alarm or event code that is associated with the event or alarm.
Note:
Table C-2
types), and
condeff
Defines the effect of the event on the system: CL indicates clearing of a standing
condition, SC indicates a standing condition is raised, and TC indicates a transition
of a condition.
ocrdat
The date the event occurred, in the format YY-MM-DD.
110 TimeProvider TL1 Reference Guide
Description
explains the fields in the alarm output:
shows all of the possible TimeProvider event codes (event condition
Table B-2
shows all of the possible TimeProvider alarm condition types.
Description
097-58001-01 Revision E – September 2006
Value
N/A
N/A
N/A
1 to 500
YY-MM-DD
YY-MM-DD
Table 2-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents