5.2 PRODUCT SETUP
Table 5–4: RECOMMENDED SETTINGS FOR USER-PROGRAMMABLE LEDS
SETTING
LED 1 operand
LED 2 operand
LED 3 operand
LED 4 operand
LED 5 operand
LED 6 operand
LED 7 operand
LED 8 operand
LED 9 operand
LED 10 operand
LED 11 operand
LED 12 operand
PATH: SETTINGS
PRODUCT SETUP
USER-PROGRAMMABLE
SELF TESTS
5
All major self-test alarms are reported automatically with their corresponding FlexLogic™ operands, events, and targets.
Most of the minor alarms can be disabled if desired.
When in the "Disabled" mode, minor alarms will not assert a FlexLogic™ operand, write to the event recorder, or display
target messages. Moreover, they will not trigger the
mode, minor alarms continue to function along with other major and minor alarms. Refer to the Relay self-tests section in
chapter 7 for additional information on major and minor self-test alarms.
To enable the Ethernet switch failure function, ensure that the
menu.
NOTE
5-44
PARAMETER
SETTING GROUP ACT 1
SETTING GROUP ACT 2
SETTING GROUP ACT 3
SETTING GROUP ACT 4
SETTING GROUP ACT 5
SETTING GROUP ACT 6
Off
Off
BREAKER 1 OPEN
BREAKER 1 CLOSED
BREAKER 1 TROUBLE
Off
USER-PROGRAMMABLE SELF TESTS
REMOTE DEVICE OFF
FUNCTION: Enabled
PRI. ETHERNET FAIL
MESSAGE
FUNCTION: Disabled
SEC. ETHERNET FAIL
MESSAGE
FUNCTION: Disabled
BATTERY FAIL
MESSAGE
FUNCTION: Enabled
SNTP FAIL
MESSAGE
FUNCTION: Enabled
IRIG-B FAIL
MESSAGE
FUNCTION: Enabled
ETHERNET SWITCH FAIL
MESSAGE
FUNCTION: Disabled
ANY MINOR ALARM
L30 Line Current Differential System
SETTING
PARAMETER
LED 13 operand
Off
LED 14 operand
BREAKER 2 OPEN
LED 15 operand
BREAKER 2 CLOSED
LED 16 operand
BREAKER 2 TROUBLE
LED 17 operand
SYNC 1 SYNC OP
LED 18 operand
SYNC 2 SYNC OP
LED 19 operand
Off
LED 20 operand
Off
LED 21 operand
AR ENABLED
LED 22 operand
AR DISABLED
LED 23 operand
AR RIP
LED 24 operand
AR LO

5.2.11 USER-PROGRAMMABLE SELF-TESTS

Range: Disabled, Enabled. Valid for units that contain a
CPU with Ethernet capability.
Range: Disabled, Enabled. Valid for units that contain a
CPU with a primary fiber port.
Range: Disabled, Enabled. Valid for units that contain a
CPU with a redundant fiber port.
Range: Disabled, Enabled.
Range: Disabled, Enabled. Valid for units that contain a
CPU with Ethernet capability.
Range: Disabled, Enabled.
Range: Disabled, Enabled.
or
messages. When in the "Enabled"
ANY SELF-TEST
ETHERNET SWITCH FAIL FUNCTION
5 SETTINGS
is "Enabled" in this