A.1 PARAMETER LISTS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 4 of 8)
A
ADDRESS
FLEXANALOG NAME
9029
Prefault Ib Ang [0]
9030
Prefault Ic Mag [0]
9032
Prefault Ic Ang [0]
9033
Prefault Va Mag [0]
9035
Prefault Va Ang [0]
9036
Prefault Vb Mag [0]
9038
Prefault Vb Ang [0]
9039
Prefault Vc Mag [0]
9041
Prefault Vc Ang [0]
9042
Postfault Ia Mag [0]
9044
Postfault Ia Ang [0]
9045
Postfault Ib Mag [0]
9047
Postfault Ib Ang [0]
9048
Postfault Ic Mag [0]
9050
Postfault Ic Ang [0]
9051
Postfault Va Mag [0]
9053
Postfault Va Ang [0]
9054
Postfault Vb Mag [0]
9056
Postfault Vb Ang [0]
9057
Postfault Vc Mag [0]
9059
Postfault Vc Ang [0]
9060
Fault Type [0]
9061
Fault Location [0]
9216
Synchchk 1 Delta V
9218
Synchchk 1 Delta F
9219
Synchchk 1 Delta Phs
9220
Synchchk 2 Delta V
9222
Synchchk 2 Delta F
9223
Synchchk 2 Delta Phs
9344
Local IA Mag
9346
Local IB Mag
9348
Local IC Mag
9350
Terminal 1 IA Mag
9352
Terminal 1 IB Mag
9354
Terminal 1 IC Mag
9356
Terminal 2 IA Mag
9358
Terminal 2 IB Mag
9360
Terminal 2 IC Mag
9362
Diff Curr IA Mag
9364
Diff Curr IB Mag
9366
Diff Curr IC Mag
9368
Local IA Angle
9369
Local IB Angle
9370
Local IC Angle
9371
Terminal 1 IA Angle
9372
Terminal 1 IB Angle
9373
Terminal 1 IC Angle
A-4
UNITS
DESCRIPTION
Degrees
Fault 1 pre-fault phase B current angle
Amps
Fault 1 pre-fault phase C current magnitude
Degrees
Fault 1 pre-fault phase C current angle
Volts
Fault 1 pre-fault phase A voltage magnitude
Degrees
Fault 1 pre-fault phase A voltage angle
Volts
Fault 1 pre-fault phase B voltage magnitude
Degrees
Fault 1 pre-fault phase B voltage angle
Volts
Fault 1 pre-fault phase C voltage magnitude
Degrees
Fault 1 pre-fault phase C voltage angle
Amps
Fault 1 post-fault phase A current magnitude
Degrees
Fault 1 post-fault phase A current angle
Amps
Fault 1 post-fault phase B current magnitude
Degrees
Fault 1 post-fault phase B current angle
Amps
Fault 1 post-fault phase C current magnitude
Degrees
Fault 1 post-fault phase C current angle
Volts
Fault 1 post-fault phase A voltage magnitude
Degrees
Fault 1 post-fault phase A voltage angle
Volts
Fault 1 post-fault phase B voltage magnitude
Degrees
Fault 1 post-fault phase B voltage angle
Volts
Fault 1 post-fault phase C voltage magnitude
Degrees
Fault 1 post-fault phase C voltage angle
---
Fault 1 type
---
Fault 1 location
Volts
Synchrocheck 1 delta voltage
Hz
Synchrocheck 1 delta frequency
Degrees
Synchrocheck 1 delta phase
Volts
Synchrocheck 2 delta voltage
Hz
Synchrocheck 2 delta frequency
Degrees
Synchrocheck 2 delta phase
Amps
Local terminal phase A current magnitude
Amps
Local terminal phase B current magnitude
Amps
Local terminal phase C current magnitude
Amps
Remote terminal 1 phase A current magnitude
Amps
Remote terminal 1 phase B current magnitude
Amps
Remote terminal 1 phase C current magnitude
Amps
Remote terminal 2 phase A current magnitude
Amps
Remote terminal 2 phase B current magnitude
Amps
Remote terminal 2 phase C current magnitude
Amps
Differential current phase A magnitude
Amps
Differential current phase B magnitude
Amps
Differential current phase C magnitude
Degrees
Local terminal current phase A angle
Degrees
Local terminal current phase B angle
Degrees
Local terminal current phase C angle
Degrees
Remote terminal 1 current phase A angle
Degrees
Remote terminal 1 current phase B angle
Degrees
Remote terminal 1 current phase C angle
L30 Line Current Differential System
APPENDIX A